CJX2 Magnetic AC Contactor 3-pole across the line contactors are designed for controlling power circuits up to 690 VAC and 220 VDC. They typically are used with 3-phase motors, non-inductive or slightly inductive loads. CJX2 Magnetic AC contactors feature block type design and include an electronic coil interface which accepts a wide control voltage. Four coils cover control voltages between 24…500 V 50/60 Hz or 20…500 VDC. CJX2 contactors are also designed to handle large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change.

 

  • AC or DC operated control circuits
  • Reduced panel energy consumption
  • Can withstand short voltage dips & sags
  • Mutual cooperation with thermal overload protection
  • Auxiliary contact blocks
  • Wide range of accessories
GET QUOTE NOW
Type CJX2-D09 CJX2-D12 CJX2-D18 CJX2-D25 CJX2-D32 CJX2-D40 CJX2-D50 CJX2-D65 CJX2-D80 CJX2-D95
Rated workingcurrent (A) AC3 9 12 18 25 32 40 50 65 80 95
AC4 3.5 5 7.7 8.5 12 18.5 24 28 37 44
Standardpower ratingsof 3-phasemotors50/60Hz incategory AC-3 220/230V 2.2 3 4 5.5 7.5 11 15 18.5 22 25
380/400V 4 5.5 7.5 11 15 18.5 22 30 37 45
415V 4 5.5 9 11 15 22 25 37 45 45
500V 5.5 7.5 10 15 18.5 22 30 37 55 55
660/690V 5.5 7.5 10 15 18.5 30 33 37 45 55
Rated heat current (A) 20 20 32 40 50 60 80 80 125 125
Electrical life AC3 (x104) 100 100 100 100 80 80 60 60 60 60
AC4 (x104) 20 20 20 20 20 15 15 15 10 10
Mechanical life (x104) 1000 1000 1000 1000 800 800 800 800 600 600
Number of the contacts 3P+NO 3P+NC+NO
3P+NC
Type CJX2-D115 CJX2-D150 CJX2-D170 CJX2-D205 CJX2-D245 CJX2-D300 CJX2-D410 CJX2-D475 CJX2-D620
Rated workingcurrent (A) AC3 115 150 170 205 245 300 410 475 620
AC4 52 60 75 85 105 117 138 147 180
Standard powerratings of 3-phase motors50/60Hz incategory AC-3 220/230V 30 40 55 63 75 100 110 147 200
380/400V 55 75 90 110 132 160 220 265 335
415V 59 80 100 110 132 180 220 280 375
500V 75 90 110 129 160 200 250 355 400
660/690V 80 100 110 129 160 220 280 355 450
Rated heat current (A) 200 250 250 275 315 400 500 700 1000
Electrical life AC3 (x104) 200 60 60 50 50 50 30 30 20
AC4 (x104) 15 15 15 15 15 15 8 8 5
Mechanical life (x104) 300 300 300 300 300 300 300 100 100 100

Standard Control Circuit Voltage

Volts 24 42 48 110 220 230 240 380 400 415 440 500 600
50Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5
60Hz B6 D6 E6 F6 M6 U6 Q6 R6
50/60Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7

LC1 Magnetic AC Contactor

Type A B C D E a b Φ
CJX2-D09~12 47 76 82 113 133 34/35 50/60 4.5
CJX2-D18 47 76 87 118 138 34/35 50/60 4.5
CJX2-D25 57 86 95 126 146 40 48 4.5
CJX2-D32 57 86 100 131 151 40 48 4.5
CJX2-D40~65 77 129 116 145 165 40 100/110 6.5
CJX2-D80~95 87 129 127 175 195 40 100/110 6.5

AC CONTACTOR D0115-D620

Type A B C b1 P Q S Q1 M N L Φ Ga Ha
CJX2-D115 158 120 132 158 35 60 17 25 134 96.2 75 M6
CJX2-D150 158 120 132 158 35 60 17 25 134 96.2 75 M6
CJX2-D170 158 120 132 158 35 60 17 25 134 96.2 75 M6
CJX2-D205 168.5 174 181 137 40 69 20 59.4 154 127 113.5 M8 80 120-106
CJX2-D245 168.5 197 181 137 48 69 25 51.5 172 127 113.5 M10 80 120-106
CJX2-D300 213 206 219 145 48 91 25 74 181 158 145 M10 80 120-106
CJX2-D410 213 206 219 209 48 91 25 74 181 158 145 M10 80 120-106
CJX2-D475 233 238 232 209 55 108 30 77 208 172 146 M10 80 180
CJX2-D620 309 304 255 280 80 140 40 89 264 202 155 M12 80 180

Auxiliary contact block

Appellation Type
Auxiliary instantaneous
contactor block,contactor I
LA1-DN10C CJX2-1
LA1-DN01C
Appellation Type
Auxiliary instantaneous
contactor block,contactor II
LA1-DN11C CJX2-2
LA1-DN20C
LA1-DN02C
Appellation Type
Auxiliary instantaneous
contactor block,contactor IV
LA1-DN40C CJX2-3
LA1-DN31C
LA1-DN22C
LA1-DN13C
LA1-DN04C
Appellation Type
Auxiliary instantaneous
contactor block,contactor IV
LA1-DN40C CJX2-4
LA1-DN31C
LA1-DN22C
LA1-DN13C
LA1-DN04C
Appellation Type
Side-mounted auxiliary module LA8-DN11C CJX2-5
LA8-DN20C

LA2 time delay auxiliary contact block

Appellation Type
Auxiliary instantaneouscontactor block,contactor IV 0.1…3S LA2-DT0 CJX2-6
0.1…30S LA2-DT2
10…180S LA2-DT4
1…30S LA2-DS2
Appellation Type
Time delay auxiliary contactorblock releasing and delay 0.1…3S LA2-DT0 CJX2-7

CJX2-AC Contactor